1. SPECIFICATIONS
MECHANICAL ELECTRICAL/ENVIRONMENTAL
Physical Size:
Height: 2-5/8” [66mm]
Depth: 1-5/8” [41mm] (from mounting
surface)
Overall Length:
36” Door = 34-1/2” [876mm]
42” Door = 40-1/2” [1029mm]
48” Door = 46-1/2” [1181mm]
Operating Force (Maximum): 15 Lbs. [66.7N]
Maximum Recommended Current:
1.5 Amps @ 30VDC
Environmental (Recommended):
Temperature: 32ºF to 120ºF [0ºC to 49ºC]
Humidity: 10% to 90% RH
2. COMPONENTS
EMB UNIT PACKAGE
MOUNTING HARDWARE
4X – 1/4-20 Blind Nut 4X – External Tooth Washer 2X – End Mount Retainer
4X – 1/4-20 x 1” Long
Phillips Pan Head
1X – Blind Nut Installation Tool 2X – E-clip
T
SB-C
Mounting
Hardware
EMB
Push To Exit
Label
Vedere la pagina 0
1 2 3 4 5 6 7 8

Sommario

Pagina 1 - INSTALLATION INSTRUCTIONS

Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solution

Pagina 2 - Page 2 Rev. C, 03/11

PN# 500-23130 Page 2 Rev. C, 03/11 3. DOOR PREPARATION New Installation:  With the door in the closed position, verify that the bar fits bet

Pagina 3 - Page 3 Rev. C, 03/11

PN# 500-23130 Page 3 Rev. C, 03/11 Mounting Diagram Hollow Metal (Aluminum Frame Glass) Door Preparation Shown * NOTE: Drill holes through mo

Pagina 4 - Page 4 Rev. C, 03/11

PN# 500-23130 Page 4 Rev. C, 03/11 4. INSTALLATION Mount Bar to Door:  Feed wire cable through hole in door, or route wire through the end

Pagina 5 - Page 5 Rev. C, 03/11

PN# 500-23130 Page 5 Rev. C, 03/11 5.1 WIRE ROUTING THROUGH END CAP (OPTIONAL) Drill End Cap:  Determine which bar end cap to feed the flex

Pagina 6 - Page 6 Rev. C, 03/11

PN# 500-23130 Page 6 Rev. C, 03/11 6. SHORTENING THE BAR (OPTIONAL) Measure for fit:  Measure the distance between stops on the door frame.

Pagina 7

PN# 500-23130 Page 7 Rev. C, 03/11 7. ELECTRICAL CONNECTION Typical Wiring Configurations: The following wiring diagrams are provided as exa

Pagina 8 - Page 8 Rev. C, 03/11

PN# 500-23130 Page 8 Rev. C, 03/11 Double Break Wiring Many installations include a controlled access device such as a digital keypad or card r